Presumed Asbestos-Containing Material (PACM) vs. Suspect Asbestos-Containing Material |
|||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
| By Mike Kindley, CIH
Occasionally questions still arise about the difference between "presumed asbestos-containing material (PACM)" and "suspect asbestos-containing material (suspect ACM)" and how these terms relate to the OSHA Asbestos Standards. In both the OSHA Construction Asbestos Standard (29 CFR 1926.1101) and the General Industry Asbestos Standard (29 CFR 1910.1001) PACM is defined as thermal system insulation (TSI) and surfacing material found in a building constructed no later than 1980. TSI is the material applied to pipes, fittings (joints, "Ts", elbows, valves, etc.), boilers, breechings, tanks, ducts or other structural components, generally to prevent heat loss or gain. Surfacing material refers to materials sprayed, troweled-on or otherwise applied to surfaces generally for acoustical, fireproofing, or other purposes. Examples of surfacing materials include decorative finishes on ceilings and walls, fireproofing on structural members, and acoustical plasters. OSHA requires that building owners identify PACM in their buildings and treat the PACM as asbestos-containing materials (ACM) until the materials are proven not to contain asbestos. Although not defined strictly as "PACM", both OSHA standards also require asphalt and vinyl flooring material installed no later than 1980 be "considered" and "treated" as asbestos-containing, until the building owner proves the flooring is not ACM. This includes not only the flooring material, but associated mastics and backings. Suspect ACMThe term "suspect ACM" does not appear in either of the OSHA standards. The term, however, has long been used by the asbestos industry to refer to any building material that is suspected of being asbestos-containing (based on appearance, usage, age of building, etc.), but has not been proven conclusively to be ACM (based on sampling and analysis, documentation, building records, etc). For OSHAs purposes, suspect material would include any material (including TSI, surfacing, and flooring) that a building owner suspects of containing asbestos and is found in a building constructed after 1980, or any material (excepting TSI, surfacing, and flooring) found in a building constructed prior to 1981. Other typical suspect building materials would include ceiling tiles, asbestos-cement products (Transite®), and joint compound. The exercise of due diligence (as noted in the OSHA asbestos standards) requires that, where a building owner knows or should have known that materials other than PACM are asbestos-containing, these materials must be treated as ACM until proven otherwise. A building constructed prior to 1981, therefore, could contain both PACM and suspect ACM. Newer buildings (constructed after 1980) would contain only suspect ACM. Courses of action for PACMBuilding owners with identified PACM have two courses of action under the OSHA standards: 1) rebut or disprove the PACM designation; or 2) simply continue to treat the PACM as ACM (and follow all OSHA requirements for protecting the health and safety of workers and building occupants). OSHA allows a building owner to rebut the designation of PACM in two ways:
Also, a building owner may demonstrate that flooring material is not ACM by determination of an "industrial hygienist" based upon recognized analytical techniques. If the resulting sample analyses indicates that the PACM contains more than one percent (>1%) asbestos, then it is no longer PACM, but proven ACM. If samples are negative for asbestos, then the material is proven non-ACM. Rebutting PACMThe OSHA regulations appear clear in only allowing the rebuttal of the PACM designation for materials by utilizing the AHERA protocol. Inspections and sampling performed not according to AHERA could not be used to rebut the PACM designation.
Courses of action for ACMAs with PACM, building owners with suspect ACM in their buildings have two options: 1) determine whether the materials are actually ACM and treat them accordingly; or 2) just treat the materials as ACM (and follow all OSHA requirements for protecting workers and building occupants). Building owners who do not follow one of these courses of action would not be exercising due diligence. If a building owner wishes to pursue the first option, the question then becomes, "How does a building owner determine if the suspect material is or is not ACM?" Rebutting ACMLike the requirements for rebutting PACM, an AHERA asbestos inspection would appear to be the definitive method for determining if suspect material is or is not ACM. Although this is not specifically stated in the OSHA regulations, would the exercise of due diligence not require that a building owner utilized the "state-of-the-art" method (which is the AHERA inspection) for determining if suspect material is actually ACM? OSHA, however, also allows building owners to rely on building records to show that suspect materials do or do not contain asbestos (see OSHA Directives CPL 2-2.63 (Revised) "Inspection Procedures for Occupational Exposure to Asbestos Final Rule", pg 41015 and the Standards Interpretation letter dated 08/20/1997 "Asbestos surveying and sampling associated with the remodeling, renovation, and demolition of buildings"). These records could include previous asbestos inspections, but may also include other sources of information to show that the materials contain or do not contain asbestos (e.g., as-built drawings, architectural schedules, "asbestos free" certifications, asbestos abatement reports, etc.). The inherent problem with relying on records, however, is the reliability of the records. Where some records may be accurate and complete, and can be relied upon, others may be inaccurate and incomplete, and cannot be relied upon. The building owner, again, would be required to exercise due diligence in using records to identify ACM. |
|||||||||||||||||||||||||||||
|
|
|||
|
Home | Hearing Conservation | Occupational Health | Industrial Hygiene | Indoor Air Quality | Safety | Training | Software | Equipment © 2008, Workplace Group All rights reserved. No part of this Web site may be copied or otherwise reproduced without Contact us at: Workplace Group To report problems with this web site, please e-mail the . |
|||